Effect of analyzer on determination of mixed venous PCO2 and cardiac output during exercise
L Hornby1, A L Coates, L C Lands
1Division of Respiratory Medicine, Montreal Children's Hospital-McGill University, Quebec, Canada.
Abstract:
Cardiac output (CO) during exercise can be determined noninvasively by using the indirect Fick CO2-rebreathing technique. CO2 measurements for this technique are usually performed with an infrared analyzer (IA) or mass spectrometer (MS). However, IA CO2 measurements are susceptible to underreading in the face of high O2 concentrations because of collision broadening. We compared an IA (Ametek model CD-3A) with a MS (Marquette model MGA-1100) to see the effect this would have on mixed venous PCO2 (PVCO2) and CO measurements. After calibration with room air and a gas mixture of 5% CO2-12% O2-83% N2, both devices were tested with three different gas mixtures of CO2 in O2. For each gas mixture, IA gave lower CO2 values than did the MS (4.1% CO2: IA, 3.85 +/- 0.01% and MS, 4.13 +/- 0.01%; 9.2% CO2: IA, 8.44 +/- 0.07% and MS, 9.19 +/- 0.01%; 13.8% CO2: IA, 12.57 +/- 0.15% and MS, 13.82 +/- 0.01%). Warming and humidifying the gases did not alter the results. The IA gave lower values than did the MS for eight other medical gases in lower concentrations of O2 (40-50%). Equilibrium and exponential rebreathing procedures were performed. Values determined by the IA were > 10% higher than those determined by the MS for both rebreathing methods. We conclude that all IAs must be checked for collision broadening if they are to be used in environments where the concentration of O2 is > 21%. If collision broadening is present, then either a special high O2-CO2 calibration curve must be constructed, or the IA should not be used for both arterial PCO2 and PVCO2 estimates because it may produce erroneously low PVCO2 values, with resultant overestimation of CO.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...
Oxygen Transport in the Blood
Chemical Factors Affecting Respiration Centers
CO2 has a potent influence on respiration and is strictly regulated. Under...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and HCO3− values are examined to...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...