Is measuring postnatal symphysis-fundal distance worthwhile?

E R Cluett, J Alexander, R M Pickering

    Midwifery
    |December 1, 1995
    PubMed
    Summary

    Daily measurement of postnatal symphysis-fundal distance is not precise enough for clinical use. This tape measure method should be discontinued due to high intra-observer and inter-observer variability.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Immersion in water in pregnancy, labour and birth.

    The Cochrane database of systematic reviews·2004
    Same author

    An investigation into the feasibility of comparing three management options (augmentation, conservative and water) for nulliparae with dystocia in the first stage of labour.

    Midwifery·2001
    Same author

    Gata5 is required for the development of the heart and endoderm in zebrafish.

    Genes & development·1999
    Same author

    Psychiatric comorbidity associated with DSM-IV ADHD in a nonreferred sample of twins.

    Journal of the American Academy of Child and Adolescent Psychiatry·1999
    Same author

    casanova plays an early and essential role in endoderm formation in zebrafish.

    Developmental biology·1999
    Same author

    A molecular pathway leading to endoderm formation in zebrafish.

    Current biology : CB·1999

    Area of Science:

    • Obstetrics and Gynecology
    • Maternal Health
    • Clinical Measurement

    Background:

    • Postnatal care involves monitoring uterine involution.
    • Symphysis-fundal distance (SFD) measurement is a common clinical practice.
    • Assessing the precision of SFD measurement is crucial for its clinical utility.

    Purpose of the Study:

    • To evaluate intra-observer and inter-observer variability in postnatal SFD measurements.
    • To determine if SFD measurement precision is adequate for clinical decision-making.

    Main Methods:

    • Intra-observer study: 15 midwives measured SFD on 30 women twice.
    • Inter-observer study: 13 midwives measured SFD on 24 women.
    • Repeatability coefficients were calculated to quantify measurement variability.

    Main Results:

    • Intra-observer repeatability coefficient was 2.94 cm.
    • Inter-observer repeatability coefficient was 5.01 cm.
    • Clinical practice variability is expected to exceed study findings.

    Conclusions:

    • Daily postnatal SFD measurement using a tape measure lacks sufficient precision for clinical judgments.
    • The routine use of tape measure SFD for postnatal assessment should cease.
    • Further research is needed on uterine fundal palpation for assessing involution.