Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

[Thromboembolic complications after aortic valve prosthesis]

A S Sharykin

    Kardiologiia
    |January 1, 1977
    PubMed
    Summary

    Aortic valve replacement outcomes show that anticoagulation with Phenylin significantly reduces thromboembolism risk. Patients not receiving anticoagulants experienced higher complication rates, impacting long-term survival.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Sudden Death In Sports: Modern Concepts.

    Kardiologiia·2024
    Same author

    [Myocardial fatty dystrophy in patients with Fallot tetralogy].

    Arkhiv patologii·2003
    Same author

    [Hematological characteristics in blood autoanalysis in children with congenital heart defects].

    Klinicheskaia laboratornaia diagnostika·2002
    Same author

    [Morphofunctional analysis of right ventricle cardiomyocytes in patients with Fallot's tetrad during first year of life].

    Arkhiv patologii·2001
    Same author

    [The successful correction of multiple defects of the interventricular septum by an approach via the left ventricle].

    Grudnaia i serdechno-sosudistaia khirurgiia·1993
    Same author

    [The use of polytetrafluoroethylene vascular prostheses (Gore-Tex) for subclavian-pulmonary anastomosis in children with tetralogy of Fallot].

    Grudnaia i serdechno-sosudistaia khirurgiia·1992

    Area of Science:

    • Cardiovascular Surgery
    • Medical Complications
    • Prosthetic Heart Valves

    Context:

    • Aortic valve replacement (AVR) is a critical procedure for managing severe aortic valve disease.
    • Long-term outcomes and complication rates following AVR require ongoing investigation.
    • Evaluating the role of anticoagulation in mitigating postoperative complications is essential.

    Purpose:

    • To analyze the long-term survival and functional outcomes of patients undergoing aortic valve replacement.
    • To compare the incidence of thromboembolism in patients with and without anticoagulation therapy post-AVR.
    • To assess the impact of anticoagulation on the stability of good results after aortic valve surgery.

    Summary:

    • This study analyzed 155 patients post-aortic valve replacement over 1-11 years.
    • Thromboembolism was the primary complication affecting late survival and outcomes.
    • Patients treated with Phenylin (anticoagulant) had significantly lower thromboembolism rates than those without anticoagulation.

    Impact:

    • Anticoagulation therapy, specifically Phenylin, appears crucial in reducing thromboembolic complications after aortic valve replacement.
    • Findings suggest that optimizing anticoagulation management can improve long-term survival and functional outcomes in AVR patients.
    • This research provides valuable data for clinical decision-making regarding postoperative anticoagulation strategies in aortic valve surgery.