[Concentrate of coagulation factor IX: viral validation of the thermoinactivation process]
R Zahorska1, I Buchowicz, A Ejduk
1Centralne Laboratorium Surowic i Szczepionek w Warszawie.
Acta Haematologica Polonica
|January 1, 1995
Abstract:
The coagulation factor IX obtained at the Institute of Haematology and Transfusion in Warsaw was subjected to virological validation. Two lipide enveloped viruses were used: HSV-1 and Sindbis which may be a model for the viruses of B and C types in hepatitis. It was shown that heating of the freeze-drying preparations at 80 degrees C during 72 hrs leads to full inactivation of the added model viruses.