Related Experiment Video
Updated: Aug 30, 2026

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
A model for multiple subcutaneous insulin injections developed from individual diabetic patient data
1Chemical Engineering Department, University of Wisconsin-Madison 53706, USA.
Abstract:
Many diabetic patients taking multiple subcutaneous insulin injections cannot adjust their dosage appropriately to maintain blood glucose within a normal range. It is hard to predict how dosage changes and physiological fluctuations affect insulin levels and subsequently glucose control. To examine these issues, we have developed a model representing the link between dosage and blood insulin levels. Our model adequately predicts insulin concentrations for individual patients and could be incorporated into an overall glucose-insulin representation. More importantly, parameter and sensitivity analysis results highlight insulin kinetic features that are difficult to isolate in a clinical setting and that may significantly influence glucose dynamics. For example, large interpatient variation, measured quantitatively by model parameters, emphasizes the need for individualized design of insulin regimens. Intrapatient variations are also large in some patients. Improved control for these patients may only be possible through more frequent sampling and control action. The sensitivity coefficient for absorption suggests a significant overlapping injection effect that is not considered in present patient management strategies.
Related Concept Videos
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant, half-life,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Drug Accumulation During Multiple Dosing: Repetitive IV Injections
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into rapid-acting...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...

