Multicenter German reference data base for peripheral quantitative computer tomography

P Schneider1, S Butz, B Allolio

  • 1Klinik und Poliklinik für Nuklearmedizin, Universität Würzburg, Germany.

Technology and Health Care : Official Journal of the European Society for Engineering and Medicine
|October 1, 1995
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Different Glymphatic Kinetics in Spontaneous Intracranial Hypotension.

AJNR. American journal of neuroradiology·2024
Same author

Spinal dementia: Don't miss it, it's treatable.

Neuroradiology·2024
Same author

Freiburg Neuropathology Case Conference: : 68-Year-Old Patient with Slurred Speech, Double Vision, and Increasing Gait Disturbance.

Clinical neuroradiology·2024
Same author

Highly variable sensitivity of five binding and two bio-assays for TSH-receptor antibodies.

Journal of endocrinological investigation·2016
Same author

Prevalence of Malignancies in Patients With Primary Aldosteronism.

The Journal of clinical endocrinology and metabolism·2016
Same author

Comparison of dual-energy X-ray absorptiometry with six quantitative ultrasonometry devices in women with hip fractures.

Climacteric : the journal of the International Menopause Society·2014
Same journal

Retraction Notice: Regulation of skeletal myogenesis in C2C12 cells through modulation of Pax7, MyoD, and myogenin via different low-frequency electromagnetic field energies.

Technology and health care : official journal of the European Society for Engineering and Medicine·2026
Same journal

The role of digital resources in surgical education: An analysis of YouTube videos on dynamic stabilization.

Technology and health care : official journal of the European Society for Engineering and Medicine·2026
Same journal

Behavioral patterns in iGaming across territories: Psychiatric and AI-driven insights via the internet of behavior.

Technology and health care : official journal of the European Society for Engineering and Medicine·2026
Same journal

Leveraging personal health records for early heart failure risk prediction through AI-driven modeling.

Technology and health care : official journal of the European Society for Engineering and Medicine·2026
Same journal

From data to prevention: A systematic review of artificial intelligence applications in sports injury prediction.

Technology and health care : official journal of the European Society for Engineering and Medicine·2026
Same journal

Leadership styles and work outcome in healthcare sector: Insights from bibliometric analysis.

Technology and health care : official journal of the European Society for Engineering and Medicine·2026
See all related articles

A validated reference database for bone densitometry was established in Germany using a forearm phantom. This ensured consistent distal radius measurements across multiple peripheral quantitative computed tomography (pQCT) devices.

Area of Science:

  • Medical Imaging
  • Bone Densitometry
  • Biomedical Engineering

Background:

  • Widespread use of bone densitometers necessitates a validated reference population database in Europe.
  • Peripheral quantitative computed tomography (pQCT) devices require cross-calibration for accurate bone density measurements.

Purpose of the Study:

  • To establish a validated reference population database for distal radius measurements in Germany.
  • To cross-calibrate pQCT devices used in a multicenter study.

Main Methods:

  • Utilized a semianthropomorphic forearm cross-calibration phantom (EFP) developed by the European Union's COMAC-BME program.
  • Cross-calibrated pQCT devices at four German centers participating in a multicenter study.
  • Collected data from 723 women and 208 men to form the normal database.

Related Experiment Videos

Main Results:

  • No significant regional differences were found in the data collected from different centers.
  • Proper calibration of pQCT devices was monitored using the EFP and the normal database.
  • Ensured uniform reference data for distal radius measurements across all participating pQCT devices.

Conclusions:

  • The study successfully established a uniform reference database for distal radius measurements in Germany.
  • The use of the EFP and multicenter collaboration ensured consistent and reliable bone density data.
  • This facilitates accurate interpretation of bone densitometry results across different devices and locations.