Single-photon emission tomographic quantification in spherical objects: effects of object size and background

F Zito1, M C Gilardi, P Magnani

  • 1INB-CNR, University of Milan, Institute H San Raffaele, Milan, Italy.

European Journal of Nuclear Medicine
|March 1, 1996
PubMed
Summary

This study presents a new method for accurately measuring radioactivity in small structures using single-photon emission tomographic (SPET) imaging. The validated technique corrects for imaging errors, improving quantification accuracy in clinical applications like tumor studies.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Cytofluorimetric study of cerebrospinal fluid at staging of diffuse large B cell lymphoma.

Journal of chemotherapy (Florence, Italy)·2026
Same author

Refining the role of selinexor in multiple myeloma: strategic use in a shifting treatment landscape.

ESMO open·2026
Same author

Preliminary insights on the daily rhythm of CRP and IL-6 in athletic horses.

Journal of equine veterinary science·2025
Same author

Corrigendum to "First-line therapy with daratumumab, lenalidomide and dexamethasone for patient with POEMS syndrome: A case report" [Leukemia Research Reports (2024) Volume 22, 100491].

Leukemia research reports·2025
Same author

Investigation of the impact of seasonal climate conditions on feed intake and body weight in horses.

International journal of biometeorology·2025
Same author

First-line therapy with daratumumab, lenalidomide and dexamethasone for patient with POEMS syndrome: A case report.

Leukemia research reports·2024

Area of Science:

  • Medical Imaging
  • Nuclear Medicine
  • Radiochemistry

Background:

  • Accurate quantification of radioactivity concentration in small anatomical structures is challenging in single-photon emission tomographic (SPET) imaging.
  • Partial volume effects and spillover significantly impact quantitative accuracy in SPET.
  • Existing methods require robust models to address these limitations.

Purpose of the Study:

  • To establish and validate a method for SPET quantification of radioactivity concentration in small anatomical structures.
  • To adapt and apply a theoretical model (Kessler et al., 1984) for SPET.
  • To assess the accuracy and applicability of the method in phantom and patient studies.

Main Methods:

  • Utilized a theoretical model to describe spatial resolution effects (partial volume and spillover) on radioactivity quantification.

Related Experiment Videos

  • Validated the model using SPET phantom experiments with varying object sizes and source/background contrasts.
  • Assessed method accuracy by comparing model-corrected and true radioactivity concentration ratios.
  • Main Results:

    • Demonstrated good agreement between model-predicted and SPET-measured radioactivity concentration ratios in phantom studies.
    • Achieved accuracy within 8.5% over a range of object sizes (9.4-36.5 mm).
    • Successfully applied the method to quantify radioactivity in ocular melanoma using SPET monoclonal antibody imaging.

    Conclusions:

    • The validated method effectively corrects for partial volume effects and spillover in SPET.
    • The model is suitable for specific clinical situations involving spherical anatomical structures (e.g., neuroreceptor and tumor imaging).
    • This approach enhances the reliability of quantitative SPET analysis in clinical practice.