Related Experiment Video
Updated: Aug 19, 2026

The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation
Published on: February 28, 2012
Interference with anticoagulation monitoring by procainamide-induced lupus anticoagulant
M T Metzdorff1, K S Hanses, G L Wright
1Lagacy Good Samaritan Hospital and Medical Center, Portland 97210, USA.
Abstract:
A patient scheduled for coronary revascularization was discovered to have elevated partial thromboplastin and activated clotting times. Preoperative testing revealed a lupus anticoagulant, probably secondary to long-term procainamide therapy. The resultant inability to use conventional anticoagulation monitoring for cardiopulmonary bypass was solved by direct measurement of heparin concentration. Operation and recovery were uneventful, and the patient was treated with long-term warfarin anticoagulation for this hypercoagulable state.