Related Experiment Video
Updated: Aug 15, 2026

Investigations on the Ga(III) Complex of EOB-DTPA and Its 68Ga Radiolabeled Analogue
Published on: August 17, 2016
Phase II clinical evaluation of Gd-EOB-DTPA: dose, safety aspects, and pulse sequence
P Reimer1, E J Rummeny, K Shamsi
1Institute of Clinical Radiology, Westfalian Wilhelms-University Muenster, Germany.
Purpose:
To investigate the efficacy of gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) in the detection of focal liver lesions with respect to dose, side effects, and pulse sequence.
Materials And Methods:
A randomized double-blinded trial was performed in 33 patients with focal solid liver lesions. A bolus of Gd-EOB-DTPA, a liver-specific contrast agent, was intravenously administered at three different doses (12.5, 25, and 50 mumol per kilogram of body weight). Magnetic resonance imaging with different T1-weighted techniques was performed 20 and 45 minutes after administration of Gd-EOB-DTPA. Changes in liver signal intensity, lesion-liver contrast-to-noise ration (C/N), detectable liver lesions, side effects, and adverse events were evaluated.
Results:
Gd-EOB-DTPA significantly (P < .05) increased liver signal intensity and lesion-liver C/N within the dose range tested. Lesion detection was improved 20 and 45 minutes after administration of Gd-EOB-DTPA. A dose of 12.5 mumol was sufficient for the detection of focal liver lesions, and the breath-hold, T1-weighted, fast low-angle shot pulse sequence was the most useful. No significant changes in vital signs, clinical laboratory test results, and urinalysis were observed.
Conclusion:
Gd-EOB-DTPA is an efficient, diagnostically useful, and safe contrast agent.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography