Stress and strain distribution within the intact femur: compression or bending?
Related Experiment Video
Updated: Nov 5, 2026

Imaging of the Microstructural Failure Mechanism in the Human Hip
Published on: September 29, 2023
M E Taylor1, K E Tanner, M A Freeman
1IRC in Biomedical Materials, Queen Mary and Westfield College, London, UK.
Abstract:
The aim of this research was to test the hypothesis that the intact femur is loaded predominately in compression. The study was composed of two parts: a finite element analysis of the intact femur to assess if a compressive stress distribution could be achieved in the diaphyseal region of the femur using physiological muscle and joint contact forces; a simple radiological study to assess the in vivo deflections of the femur during one legged stance. The results of this investigation strongly support the hypothesis that the femur is loaded primarily in compression, and not bending as previously thought. The finite element analysis demonstrated that a compressive stress distribution in the diaphyseal femur can be achieved, producing a stress distribution which appears to be consistent with the femoral cross-sectional geometry. The finite element analysis also predicted that for a compressive load case there would be negligible deflections of the femoral head. The radiological study confirmed this, with no measurable in vivo deflection of the femur occurring during one legged stance.
More Related Videos
Related Concept Videos
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to its distance...
Plastic Deformations
Plastic Deformations
Residual Stresses in Bending
Bending of Curved Members - Strain Analysis
The important part of bending analysis for such a member is the...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...