Related Experiment Video
Updated: Oct 8, 2026

A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
Noninvasive physiologic monitoring of high-risk surgical patients
W C Shoemaker1, C C Wo, M H Bishop
1Department of Emergency Medicine, King-Drew Medical Center, University of Southern California School of Medicine, Los Angeles, USA.
Objectives:
To study the feasibility of multicomponent noninvasive monitoring, consisting of a new bioimpedance method for estimating cardiac output together with routine pulse oximetry and transcutaneous oximetry, and to compare physiologic data obtained noninvasively with hemodynamic and oxygen transport data obtained by standard invasive pulmonary artery thermodilution catheter to evaluate circulatory function in high-risk surgical patients.
Design:
Prospective descriptive analysis of the time course of physiologic patterns in surgical patients.
Setting:
University-run county hospital.
Patients:
Seventy-one consecutively monitored, high-risk critically ill surgical patients in their perioperative period.
Outcome Measures:
Simultaneous measurements by invasive and noninvasive methods to describe and compare the temporal physiologic patterns of survivors and nonsurvivors.
Results:
The new impedance cardiac output estimations closely approximated those of the thermodilution method (r = 0.82, P < .001). Episodes of hypotension, tachycardia, low cardiac index, arterial hemoglobin desaturation, low transcutaneous oximetry, reduced oxygen delivery, and low oxygen consumption occurred with both groups but were more pronounced in the nonsurvivors than in the survivors. Noninvasive monitoring provided information similar to that of the thermodilution method. Both approaches indicated low flow and poor tissue perfusion (oxygenation) that was worse in the nonsurvivors.
Conclusions:
The multicomponent noninvasive monitoring provides continuous online, real-time displays of physiologic data that allow immediate recognition of circulatory dysfunction as well as the means to titrate therapy to appropriate predetermined therapeutic goals. The noninvasive systems are easy to apply, safe, inexpensive, reasonably accurate, and cost-effective.
More Related Videos
06:18A Bedside, Single Burr Hole Approach to Multimodality Monitoring in Severe Brain Injury
Published on: March 26, 2019
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Holter Monitor: 24-Hour Monitoring
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Peripheral Artery Disease V: Postoperative Nursing Management
Aneurysm IV: Nursing Management