Related Experiment Video
Updated: Aug 14, 2026

Scanning Skeletal Remains for Bone Mineral Density in Forensic Contexts
Published on: January 29, 2018
A survey of dual-energy X-ray absorptiometry (DEXA) normal reference ranges used within the UK and their effect on
A Simmons1, M J O'Doherty, S F Barrington
1East Kent Osteoporosis Screening and Research Unit, Kent and Canterbury Hospital, UK.
Abstract:
Differences between dual-energy X-ray absorptiometry (DEXA) normal ranges can lead to patients being characterized as osteoporotic using one range and normal using another. To investigate the diversity of normal ranges used within the UK, a survey of all DEXA sites was carried out with a 60.6% response rate. The effect of the different ranges was evaluated by translating each range to an equivalent range for a Norland XR-26 system and applying the ranges to stratify a representative sample of over 1000 patients into grades of bone density based on percentages of age-matched mean BMD, Z-scores and T-scores. The effect of femoral neck and P/A spine L2-L4 regions was considered both separately and jointly. Large differences between the normal ranges were apparent, which resulted in the classification of the number of patients with a Z-score of less than -2.0 varying by a factor of more than 20 for the femoral neck and more than 3 for the spine. The number of patients defined as osteoporotic by a T-score less than -2.5 varied from none to over one-third of patients for the hip and by a factor of almost 3 for the spine. The exclusion criteria used for construction of the normal ranges varied markedly with none constructed using population-based sampling. Smoothing of normal ranges was carried out by DEXA manufacturers, while local normal ranges made use of raw unprocessed data. There is reason to question the validity of such processing. We recommend the construction of a unified UK normal range applicable to all UK DEXA systems in order to harmonize patient management and care.
More Related Videos
07:44Evaluation of Changes in Hydration and Body Cell Mass with Bioelectrical Impedance Analysis after Exercise Program for Rheumatoid Arthritis Patients
Published on: July 14, 2023
09:02Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
Related Concept Videos
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
X-ray Imaging
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...