Related Experiment Video
Updated: Aug 2, 2026

Non-invasive Assessment of Microvascular and Endothelial Function
Published on: January 29, 2013
Plethysmography: safety, effectiveness, and clinical utility in diagnosing vascular disease
Abstract:
Plethysmography, a semiquantitative method of measuring segmental blood flow and velocity in the carotid and peripheral vascular systems, is safe, easy to perform, and inexpensive. Impedance, strain guage, air, and photoelectric plethysmographic methods are assessed in this publication for their relative safety, efficacy, and clinical utility in diagnosing vascular disease. Clinical evidence has demonstrated, for example, that oculoplethysmography is not a reliable screening test for carotid artery disease, particularly in bilateral disease and nonocclusive unilateral disease. Oculoplethysmography is thus no longer recommended for the diagnosis of carotid artery disease. Impedance, strain guage, and photoplethysmography methods can be used for the initial evaluation of acute and chronic venous insufficiency, although there is great variability in the reliability of these tests to predict venous disease in the presence of nonobstructive thrombi and comorbid conditions. Strain guage and photoelectric plethysmography can be safely used for the evaluation of peripheral arterial disease. But surgical candidates for arterial reconstruction and some venous disorders may require additional imaging such as duplex ultrasound, venography, or arteriography for anatomic information that is not elucidated by plethysmography. The plethysmographic techniques reviewed in this assessment, evaluating the ability to predict the presence of flow reduction in the carotid and peripheral circulations, are based on the technical performance of the tests as compared with a reference method. Establishing evidence-based conclusions proved difficult in light of biases such as nonrandomization, unstated patient selection criteria, poor followup of patients, and lack of blindness in some studies.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies

