Finapres tracking of systolic pressure and baroreflex sensitivity improved by waveform filtering
Related Experiment Video
Updated: Nov 5, 2026

Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
P Gizdulich1, B P Imholz, A H van den Meiracker
1Clinical Physiopathology Department, University of Florence, Italy.
Objective:
Arterial pressure waveforms distort between brachial and finger arteries, causing differences mainly in systolic pressure. Distortion, reportedly, can be removed by applying a waveform filter to the finger pressure.
Design:
We analysed the data from two studies that detected discrepancies in systolic tracking between Finapres and brachial pressures. The first set comprised waveforms of seven volunteers during incremental bicycle exercise to exhaustion and the second set comprised waveforms of eight volunteers during increasing phenylephrine infusion.
Methods:
We applied the filter and compared 1 min averaged unfiltered and waveform-filtered finger and brachial pressures.
Results:
During exercise, finger systolic pressure overestimated brachial increasingly, from 7(SD 10) mmHg at rest to 27(17) mmHg at maximal exertion. Differences were reduced by waveform filtering from 3 (SD 9)mmHg at rest to 1 (SD 15)mmHg at maximal exertion. During phenylephrine infusion finger systolic pressure overestimated brachial pressure, but the magnitude of the overestimate decreased from 14 (SD 15)mmHg at baseline to -1(SD 16)mmHg at maximal rate. After waveform filtering overestimation was an almost constant 6(SD 11)mmHg. Median baroreflex sensitivities from brachial, unfiltered and waveform-filtered finger pressure were 5.8, 7.5 and 5.3 ms/mmHg and correlation increased after filtering. The results indicate improved systolic pressure tracking after waveform filtering.
Conclusions:
Finger pressure distortion follows a general pattern correctable by waveform filtering. Waveform filtering allows a 'brachial' view to be obtained from Finapres data.
More Related Videos
11:08Novel Approach for Simultaneous Recording of Renal Sympathetic Nerve Activity and Blood Pressure with Intravenous Infusion in Conscious, Unrestrained Mice.
Published on: February 14, 2018
11:26Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Assessment of blood pressure in brachial artery(two-step method)