Related Experiment Videos
Reliability and comparison of RPE during variable and constant exercise protocols performed by older women
D L Wenos1, J P Wallace, P R Surburg
1Department of Kinesiology, James Madison University, VA 22807, USA.
International Journal of Sports Medicine
|April 1, 1996
Summary
Older women aged 60-75 perceived exercise intensities differently based on protocol. The 50% peak oxygen uptake intensity was most reliably perceived, suggesting its use as a marker for exertion in older adults.
Area of Science:
- Exercise Physiology
- Gerontology
- Perception Science
Background:
- Assessing exercise intensity perception in older women is crucial for effective and safe training.
- Understanding reliability of perceived exertion aids in exercise prescription for this demographic.
Purpose of the Study:
- To determine if women aged 60-75 perceive different exercise intensities within a series distinctly.
- To identify if a specific exercise intensity is perceived more reliably by this age group.
Main Methods:
- Twenty-four women (mean age 65 years) underwent a graded exercise test to determine peak oxygen uptake (VO2max).
- Participants were assigned to either a variable, randomized protocol (GP1) or constant intensity protocols (Gps2-4).
- Subjects performed exercise at 30%, 50%, and 70% of VO2max across three test days, with ratings of perceived exertion (RPE) recorded.
Main Results:
- Significant differences in RPE were observed between all tested intensities and between protocols (p < 0.05).
- Women in the variable protocol (GP1) reported higher RPE than those in constant intensity protocols.
- The 50% VO2max intensity demonstrated the highest reliability (intraclass correlation coefficients R=0.97 for GP1, r=0.94 for GP3).
Conclusions:
- Older women perceive exercise intensities differently depending on whether the protocol is variable or constant.
- The 50% relative exercise intensity is a reliable perceptual marker for exertion in women aged 60-75.