The effect of left ventricular chamber compliance on early diastolic filling during coronary reperfusion
H Kunichika1, K Katayama, H Sakai
1Second Department of Interial Medicine, Yamaguchi University School of Medicine, Ube, Japan.
Insights
This study shows that improved early diastolic filling after coronary reperfusion is linked to left ventricular (LV) chamber compliance, not LV relaxation. These findings highlight the importance of operational chamber compliance in determining diastolic function post-ischemia.
Area of Science:
- Cardiology
- Physiology
- Biomedical Engineering
Background:
- Acute myocardial ischemia impairs left ventricular (LV) diastolic filling.
- Understanding the determinants of diastolic function during coronary reperfusion is crucial for patient outcomes.
Purpose of the Study:
- To assess changes in LV diastolic filling during coronary reperfusion after acute myocardial ischemia.
- To evaluate the dynamic determinants of LV diastolic filling, specifically operational chamber compliance and LV relaxation.
Main Methods:
- Utilized conductance catheter technique and high-fidelity micromanometry for LV pressure-volume relations (D-PVRs).
- Employed transesophageal pulsed Doppler echocardiography to measure transmitral flow (peak E, peak A, E/A ratio).
- Measured operational chamber compliance [(dV/dP) nadir] and time constant of LV relaxation (TC) in open-chest dogs.
Main Results:
- Myocardial ischemia led to impaired diastolic filling, characterized by increased LV end-diastolic pressure and volume, decreased peak E and E/A ratio, and prolonged TC.
- Coronary reperfusion restored D-PVRs and improved peak E and E/A ratio.
- A significant positive correlation was found between peak E and (dV/dP) nadir, but not between peak E and TC.
Conclusions:
- Improvement in diastolic filling post-reperfusion is primarily driven by enhanced early diastolic filling.
- LV operational chamber compliance, particularly in early diastole, plays a significant role in determining diastolic filling during coronary reperfusion, more so than LV relaxation properties.
Abstract:
This study was designed to assess the changes in left ventricular (LV) diastolic filling and to evaluate the dynamic determinants of LV diastolic filling during coronary reperfusion after acute myocardial ischemia. We examined LV diastolic pressure-volume relations (D-PVRs) using the conductance catheter technique with a high-fidelity micromanometer, and the transmitral flow using transesophageal pulsed Doppler echocardiography in 9 open-chest anesthetized dogs with the pericardium opened. We measured early diastolic peak flow velocity (E), late diastolic peak flow velocity (A), the ratio of peak E to peak A (E/A), operational chamber compliance at the minimum LV pressure [(dV/VdP) nadir], and the time constant of LV relaxation (TC). Acute regional myocardial ischemia was produced by occluding the proximal portion of the left anterior descending coronary artery. Data were acquired at baseline, 10 min after acute myocardial ischemia, and after 15 and 90 min of reperfusion under left atrial pacing at 100 beats/min. During myocardial ischemia, D-PVRs shifted upward and rightward on the same curvilinear relationship compared with that at baseline (LV end-diastolic pressure (LVEDP) from 7.3 to 10.5 mmHg, LVEDV from 25 to 31 ml, both p < 0.01), accompanied by a decrease in peak E and E/A (E from 41 to 25 cm/sec, E/A from 1.7 to 1.1, both p < 0.01) and a prolongation of TC (from 25.4 to 30.3 msec, p < 0.01). After coronary reperfusion, D-PVRs returned to baseline accompanied by an improvement in the peak E and E/A ratio. No significant changes in peak A were observed in any of the stages. There was no correlation between peak E and TC, however, a significant positive correlation was observed between peak E and (dV/VdP) nadir (r = 0.76, p < 0.01). In conclusion, this study demonstrated that, using pulsed Doppler echocardiography, the improvement of diastolic filling after coronary reperfusion was based mainly on changes in early diastolic filling, and that LV operational chamber compliance at early diastole, rather than a LV relaxation property, might play an important role in determining early diastolic filling during coronary reperfusion.
More Related Videos
09:20Lumped-Parameter and Finite Element Modeling of Heart Failure with Preserved Ejection Fraction
Published on: February 13, 2021
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
Related Concept Videos
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Mitral Stenosis I: Introduction
Cardiomyopathy IV: Restrictive Cardiomyopathy