Related Experiment Video
Updated: Aug 10, 2026

In Silico Modeling Method for Computational Aquatic Toxicology of Endocrine Disruptors: A Software-Based Approach Using QSAR Toolbox
Published on: August 28, 2019
Prediction of an occupational exposure limit for a mixture on the basis of its components: application to
1Center for Environmental and Occupational Health and Toxicology, University of Pittsburgh, PA 15238, USA.
Abstract:
Using a previously developed mouse bioassay, a semisynthetic metalworking fluid (MWF "B") and its major components were evaluated. In mice MWF "B" and its components produced both sensory (S) and pulmonary (P) irritation. Using respiratory frequency (f) depression, concentration-response relationships were developed for each component as well as for MWF "B." From such relationships the concentration capable of evoking a 50% decrease in mean f was determined for each component and designated as RD50S if the decrease in f was due to sensory irritation, or RD50P if the decrease in f was due to pulmonary irritation. Based on RD50P values, the results indicated that the alkanolamides, potassium soap, sodium sulfonate, and triazine components were similar in irritation potency both to one another and to MWF "B." Through an examination of potency and fractional composition it was concluded that these five components largely contributed to the irritancy of MWF "B." From the RD50P values, occupational exposure limits that would protect workers from respiratory irritation were proposed for MWF "B" and each of its components. Using the approach of the American Conference of Governmental Industrial Hygienists for mixtures, an occupational exposure limit was calculated for MWF "B" employing the component data. The two limits for MWF "B" were similar to one another, suggesting that exposure limits for MWFs may be obtained through the evaluation of the fluids themselves or through evaluation of the components.
More Related Videos
10:10Assessment of the Acute Inhalation Toxicity of Airborne Particles by Exposing Cultivated Human Lung Cells at the Air-Liquid Interface
Published on: February 23, 2020
09:29An Air-liquid Interface Bronchial Epithelial Model for Realistic, Repeated Inhalation Exposure to Airborne Particles for Toxicity Testing
Published on: May 13, 2020
Related Concept Videos
Extraction: Advanced Methods
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...