pO2 measurements in arteriolar networks
Related Experiment Video
Updated: Nov 4, 2026

Cerebral Blood Oxygenation Measurement Based on Oxygen-dependent Quenching of Phosphorescence
Published on: May 4, 2011
I P Torres Filho1, H Kerger, M Intaglietta
1Departamento de Ciências Fisiológicas, UERJ, Rio de Janeiro, Brazil.
Abstract:
Previous studies from our laboratory have shown that the average arteriolar pO2 in the hamster skinfold preparation is lower than arterial systemic pO2. In the present work we tested the hypothesis that there is a longitudinal gradient of pO2 along precapillary vessels. Experiments were performed in Syrian golden hamsters bearing a dorsal skin chamber. The oxygen-dependent quenching of phosphorescence of palladium-porphyrin complexes was used to measure intravascular pO2 in the microcirculation. Arterioles were classified in four orders according to their position in the network, first-order vessels being the entrance points. Simultaneous determinations of diameter (D), red blood cell velocity, and systemic blood gases were also made. There was a significant fall of pO2 between vessels of different orders. First-order arterioles (mean D = 64 microns) had pO2 of 51.8 +/- 9.8 mm Hg (mean +/- SD) which was equivalent to approximately equal to 73% of the arterial systemic pO2. Within the arteriolar network, further decreases of intravascular pO2 were measured, leading to a pO2 of 34.0 +/- 7.9 mm Hg in terminal arterioles (mean D = 7.7 microns). In some vessels pO2 was measured in different positions of the same arteriole. The average longitudinal arteriolar oxygen saturation gradient was 3.4 +/- 0.4 delta %/mm (range 0.8-7.2). A significant and positive correlation was found between pO2 and microhemodynamic parameters when arterioles were grouped according to their order. This relation was not significant for venules which showed a mean pO2 of 30.8 +/- 10.8 mm Hg. Tissue pO2 averaged 24.6 +/- 5.8 mm Hg. We conclude that: (1) There is an oxygen loss in arterial vessels larger than 100 micrograms in diameter, (2) arteriolar pO2 in this preparation depends on the position of the vessel within the network, (3) a substantial portion of oxygen delivery to the hamster skin is provided by the arteriolar network, and (4) only a small pO2 gradient exists between terminal arterioles and venules, suggesting that the contribution of the capillary network to tissue oxygenation is relatively small.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:44Near-Infrared Spectroscopy During Reactive Hyperemia for the Assessment of Lower Limb Vascular Function
Published on: March 22, 2024
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Arteries and Arterioles
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement