Test procedures for verification of an electron pencil beam algorithm implemented for treatment planning
M Blomquist1, M Karlsson, M Karlsson
1Radiation Physics Department, Umeå University, Sweden.
Abstract:
The calculation of an electron dose distribution in a patient is a difficult problem because of the presence of tissue and surface inhomogeneities. Verification of the dose planning system is therefore essential. In this investigation, a novel method is used to evaluate a commercially available system (Helax-TMS), at electron energies between 10 and 50 MeV, both for a conventional treatment unit and an MLC-collimated scanned beam unit with a helium-filled treatment head. First, the experiments were designed to verify the local beam database and some fundamental characteristics of the electron beam calculations. Secondly, a number of generalised situations that would be encountered in the clinical treatment planning were evaluated oblique incidence, field shaping with multi-leaf collimator, bolus edges, and air cavities. Dose distributions in two generalised anatomical phantoms simulating a neck and a nose were also analysed. The results have, when so possible, been presented as the dose ratio within the 'flattened area' for dose profiles and down to the 'treatment depth' (80% dose level) for depth doses. In the penumbra region and in the dose fall-off region, the comparison has been represented by the distance deviation between calculated and measured dose profiles or depth doses. A new tool, 'volume integration', was used to evaluate the deviations from a more clinical point of view. Most results were within +/- 2% in dose for volumes larger than a sphere with a diameter of 15 mm, or +/- 2 mm in position. Dose deviations were generally found for oblique incidences and below heterogeneities such as small air cavities and bolus edges in limited volumes.
Related Concept Videos
Strategies of Self-Presentation II: Self-Verification
Role of Communication in the Nursing Process II: Planning and Implementation
Nursing Process for Patient and Caregiver Teaching II: Planning and Implementation
Self-Evaluation: Self-Enhancement and Self-Verification
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Nursing Implementation
The five steps to implementing effective nursing care include reassessing the patient, reviewing and revising the existing nursing care plan, organizing the resources and care delivery, anticipating and preventing complications, and implementing nursing interventions.