Temperature changes in bovine mandibular bone during implant site preparation: an assessment using infra-red thermography
Related Experiment Video
Updated: Nov 4, 2026

3D Imaging of PDL Collagen Fibers during Orthodontic Tooth Movement in Mandibular Murine Model
Published on: April 15, 2021
I C Benington1, P A Biagioni, P J Crossey
1Division of Restorative Dentistry, Queen's University of Belfast, Northern Ireland, UK.
Objectives:
Changes in bone temperature during the sequence of drilling for implant site preparation using the Branemark technique were monitored using infra-red thermography.
Methods:
Bovine mandibles were used to provide cortical bone of a similar quality to human mandibular bone. To ensure the consistency in the drilling procedure, one operator used a conventional dental handpiece with a motor provided by Nobelpharma. The manufacturer's specifications were followed during the implant site preparation, except that no irrigation was employed since infra-red radiation does not transmit through water. Thermal images were recorded using the Thermovision 900 system. A sequence of images was recorded during implant site preparation. Three drills were examined in terms of temperature changes during drilling over the entire area involved. The three drills used were a round bur, which determines the site of the fixture, a spiral drill (2 mm twist drill) which establishes the direction of the implant and finally a pilot drill (3 mm) which progressively increases the diameter of the site.
Results:
Average values (n = 10 drill sequences) for maximum recorded temperature (Max T degrees C), change in temperature (delta T degrees C) from baseline and the area of involvement (mm2) for each drill in the 10 drill sequences were as follows: round, spiral (2 mm) and pilot (3 mm) drills gave maximum temperatures of 82.7 degrees C, 130.1 degrees C and 126.3 degrees C, respectively. The changes in temperature, delta T degrees C, were 45.7 degrees C, 79.0 degrees C and 78.9 degrees C for the round, 2 mm twist and 3 mm pilot drill, respectively. The average areas recorded for the round, spiral and pilot drills were 49 mm2, 140.1 mm2 and 273.0 mm2, respectively.
Conclusions:
It is concluded that the methodology employed accurately recorded temperature changes at and around the dental implant site, and provided preliminary baseline data against which the cooling efficacy of different irrigant systems may be compared.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...