Related Experiment Video
Updated: Aug 6, 2026

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
Staging non-small cell lung cancer by whole-body positron emission tomographic imaging
P E Valk1, T R Pounds, D M Hopkins
1Northern California PET Imaging Center, Sacramento 95816, USA.
Background:
A need exists for an accurate, noninvasive means of staging non-small cell lung cancer.
Methods:
A prospective evaluation of regional and whole-body positron emission tomography (PET) imaging for staging lung cancer was carried out in 99 patients. Mediastinal PET and computed tomography findings were compared with results of surgical staging in 76 patients. Those PET and computed tomography findings that indicated possible distant metastasis were compared with biopsy results and the results of clinical and imaging follow-up.
Results:
Sensitivity and specificity for the diagnosis of N2 disease were 83% and 94% for PET and 63% and 73% for computed tomography, respectively. Positron emission tomography showed previously unsuspected distant metastasis in 11 patients (11%), with no demonstrated false-positive results. Normal PET findings were obtained at distant sites of computed tomography abnormality in 19 patients (19%). Clinical and imaging follow-up in 14 of these patients showed no evidence of metastasis. In 1 case, the PET result proved to be falsely negative.
Conclusions:
Imaging with PET was more accurate than computed tomography for diagnosis of mediastinal and distant metastasis. Detection of unsuspected metastatic disease by PET may permit reduction in the number of thoracotomies performed for nonresectable disease.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET