Flow cytometrical comparison of different semi-automatic ways of measuring S-phase fractions using fresh and
Abstract:
Histopathologically normal endometrial tissue from 250 patients was prepared for DNA measurements according to the technique of Schütte, combined with the techniques of Vindelöv and Thorntwaite for formalin-fixed material; the latter methods were used alone for fresh material. To estimate the influence of different analysis methods we used two semi-automatic methods (Cellfit, MacCycle) and a manual method. Differencies between these methods were found regarding CV (the width of the peak), and S-phase fractions [S%, (S + G2)%]. We therefore conclude that histopathologically normal tissue must first be evaluated by these methods to establish the range of normal values for a certain organ/tissue, before a certain set of values are applied in the clinical situation.