Related Experiment Video
Updated: Aug 10, 2026

Urinary Bladder Distention Evoked Visceromotor Responses as a Model for Bladder Pain in Mice
Published on: April 27, 2014
Detection of urinary incontinence during ambulatory monitoring of bladder function by a temperature-sensitive device
S D Eckford1, R Finney, S R Jackson
1Department of Urodynamics, Bristol Urological Institute, UK.
Objectives:
To determine whether the difference between urinary and perineal temperatures is sufficient to allow registration of incontinent episodes by detection of temperature change alone. To design and assess the use of a diode-based temperature-sensitive device in the detection of episodes of urinary incontinence in long-term ambulatory monitoring (LTAM) studies.
Subjects And Methods:
Perineal temperature recordings were made in 46 women during various activities. A temperature-sensitive device consisting of six IN4148 diodes, spanning 5 cm, and a nearby reference negative diode, was placed in a light perineal pad and attached to a portable amplifier/digitizer and recorder. The performance of the device was determined by comparison with increases in pad weight in 51 incontinent and 23 continent control subjects.
Results:
A sufficient temperature differential existed between perineal and urinary temperature during all activities except being seated with crossed legs. Incontinence was reliably detected by the temperature-sensitive device. The device had a sensitivity of 95.2% and a specificity of 90.6% compared to a pad test.
Conclusions:
This temperature-sensitive device offers a new method for detecting urinary incontinence during LTAM studies. It can be fitted in an unobtrusive perineal pad and has a higher sensitivity and specificity for the detection of incontinence when compared to a pad test. It may also be used as a marker of voiding in ambulatory studies not employing an integrated voiding channel.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Urine Studies II: Urine Culture and Sensitivity Test