Related Experiment Video
Updated: Aug 15, 2026

Impedance Pneumography for Minimally Invasive Measurement of Heart Rate in Late Stage Invertebrates
Published on: April 4, 2020
Monitoring of heart and respiratory rates by photoplethysmography using a digital filtering technique
K Nakajima1, T Tamura, H Miike
1Department of Electrical and Electronic Engineering, Yamaguchi University, Japan.
Abstract:
An apparatus for simultaneously monitoring heart and respiratory rates was developed using photoplethysmography (PPG) and digital filters, and compared with conventional methods. The PPG signal, which includes both heart and respiratory components, was measured at the earlobe with an original transmission mode photoplethysmographic device. A digital filtering technique was used to distinguish heart and respiratory signals from the PPG signal. The cut-off frequency of the respiratory signal filter was selected automatically depending on the heart rate. Using digital filtering techniques, heart and respiratory signals were separated at rest and during exercise. The digital signal processor was employed to realize an adaptive and real-time filtering. The heart rate was calculated by the zero-crossing method and the respiratory rate from the peak interval of the filtered signal. To evaluate the newly developed monitor, an ECG for heart rate and a transthoracic impedance plethysmogram for respiratory rate were monitored simultaneously. To obtain higher heart and respiratory rates, exercise was performed on an electrical bicycle ergometer. Heart and respiratory rates calculated by the new method compare to those obtained from ECG and the transthoracic impedance plethysmogram. The maximum error of heart and respiratory rates was 10 beats/min and 7 breaths/min, respectively.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...