Related Experiment Videos
Comparison of single-breath-hold fast spin-echo sequences with routine non-breath-hold techniques: application to MRI
P S Melki1, C Argaud, M Suminski
1Service de Radiologie, Hôpital Necker, Paris, France.
Abstract:
In 24 patients presenting with 55 renal lesions (mean size, 20.8 mm), single-breath-hold (SBH) fast spin-echo (FSE) techniques allowing T1 and T2 images to be produced within 20 and 23 sec, respectively, were compared with routine non-breath-hold (NBH) spin-echo (SE) T1 and NBH-FSE T2 sequences. Contrast-to-noise ratios (CNRs) measured from SBH-FSE T1 images were an average of 97% higher than their NBH counterparts (P = .0001) and allowed an improved lesion conspicuity in 80% of the cases (P = 0.0001). For T2 imaging, SBH-FSE and NBH-FSE sequences were not statistically different with respect to lesion conspicuity (P = .55) and CNR values (P = .19). This was observed despite a 35% average decrease in CNR of SBH-FSE compared to NBH-FSE images. By reducing respiratory motion artifacts while preserving SE-like image contrast, SBH-FSE techniques have the potential to replace routine NBH sequences for an optimal diagnosis of renal masses.