Atypical antidromic resetting during programmed extrastimulation of reentrant ventricular tachycardia
K Asami1, F Suzuki, H Ashikawa
1First Department of Internal Medicine, School of Medicine, Tokyo, Japan.
Abstract:
A patient with reentrant ventricular tachycardia exhibited both the orthodromic and antidromic resetting responses at a single intracardiac recording site during programmed extrastimulation of ventricular tachycardia. The transition from orthodromic to antidromic resetting with extrastimulation demonstrated a sudden shortening in conduction interval to an electrogram recording site and unexpected identical morphology of the spontaneous and captured electrograms at that site, indicating atypical antidromic resetting. This newly observed resetting phenomenon with programmed extrastimulation suggests that the fourth entrainment criterion with overdrive pacing may likely be demonstrated in an atypical form; that is, a sudden shortening in conduction interval to an electrogram recording site may occur without any significant change in the bipolar electrogram morphology at that site when overdrive pacing is performed during tachycardia from a single pacing site at two different constant rates.