Related Experiment Videos
Determination of opiates in urine by capillary electrophoresis
R B Taylor1, A S Low, R G Reid
1Faculty of Health and Food, Robert Gordon University, Aberdeen, UK.
Abstract:
A method for the separation of a mixture of opiates comprising pholcodine, 6-monoacetylmorphine, morphine, heroin, codeine and dihydrocodeine by capillary electrophoresis using a running buffer of 100 mM disodium hydrogenphosphate at pH 6 is described. The characteristics of an analytical method based on this separation for the determination of these drugs following extraction from urine and using levallorphan as internal standard are reported. Detection limits in the region of 10 ng cm-3 are achieved when using electrokinetic injection. A comparison is made of the sensitivity and reproducibility of electrokinetic and hydrodynamic injection for these drugs. Data are presented to show the results obtained when the proposed method is applied to urine spiked with all the above opiates and also to urine from a subject following consumption of dihydrocodeine and pholcodine. The concentrations found are compared with those obtained by LC.