Related Experiment Video
Updated: Sep 22, 2026

Ferromagnetic Bare Metal Stent for Endothelial Cell Capture and Retention
Published on: September 18, 2015
Retention of esthetic veneers on primary stainless steel crowns
L H Baker1, P Moon, A P Mourino
1General Practice Department, VCU-MCV School of Dentistry, Richmond, USA.
Abstract:
The purpose of this study was to ascertain the amount of shearing force necessary to fracture, dislodge or deform the esthetic veneer facings of four commercially available veneered primary incisor stainless steel crowns. The four types tested were: Cheng Crowns, [Peter Cheng Orthodontic Laboratory]; Whiter Biter Crown II, [White Bite Inc.]; Kinder Krowns, [Mayclin Dental Studio, Inc]; and NuSmile Primary Crowns, [Orthodontic Technologies, Inc]. The crowns (#4 right central incisor) from each manufacturer were obtained with the facings attached. The crowns were soaked for ninety days and thermocycled at 4 degrees C and 55 degrees C for 500 45-second cycles. The crowns were cemented to standardized chromium cobalt metal dies. Each die was placed in to a custom holder on the Instron Universal testing machine. A force was applied at the incisal edge of the veneer at 148 degrees, (the primary interincisal angle), with a crosshead speed of 0.05 inches/minute until the veneer either fractured, dislodged or deformed. The mean force (Ibs) required +/- SD to produce failure, in descending order, was as follows: Cheng (107.8 +/- 17.3); NuSmile (100.2 +/- 18.2); KinderKrown (91.3 +/- 27.4)d Whiter Biter (81.5 +/- 21.7). To test the hypothesis of no difference among the four manufacturers, an analysis of variance was performed using PROC GLM. The resultant F statistic was 2.79 (p < 0.0543), indicating a marginally statistically significant difference in the response variable "pressure" among the four groups. A posthoc test was then performed to ascertain where these differences occurred. These results, using Turkey's studentized range test for pairwise comparisons, suggested that the only difference was between the Cheng and Whiter Biter manufacturers.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
04:23Standardized Protocol to Evaluate the Effect of Surface Treatments, Luting Cements, and Thermocycling on PEEK–Composite Bond Strength
Published on: June 9, 2026
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...