Evaluation of NCRP Report No. 49 assumptions on workloads and use factors in diagnostic radiology facilities
1St. Luke's Medical Center, Milwaukee, Wisconsin 53215, USA.
Abstract:
A survey of modern medical institutions has been performed to measure the workload and primary beam use factors used in diagnostic x-ray installations in comparison to those suggested in Report 49 of the NCRP. Seven types of radiology installations were investigated, namely general radiographic rooms, general fluoroscopic and radiographic rooms (fluoroscopic and radiographic tubes surveyed separately), chest radiographic rooms, mammographic suites, and cardiac and peripheral angiographic suites. The radiologic technique (kVp and mAs) for each exposure performed on a total of 2396 patients was recorded either manually or by a commercially-available invasive electronic sensing system. Additionally, the direction of the primary beam during the exposure was recorded. The kVp distribution of the workload data was determined and normalized per patient for each of the seven types of installations. The total average workload per patient surveyed in each type of installation is 2.5, 13, 1.5, 0.22, 6.7, 160, and 64 mA min per patient for the above installation types. For general radiographic rooms the primary beam was directed at the floor for 69% of the total workload, with the remaining 21.5%, 6.5% and 1.6% of the workload directed toward three walls. When multiplied by the average number of patients examined weekly in each type of installation, the mean weekly workloads observed are 270, 230, 35, 44, 320, 3100, and 1400 mA min for the above-listed types of installations. Additionally, a significant fraction of the observed workloads occur at potentials much less than the kVp values typically assumed for radiation shielding.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...