Separation of arterial pressure waves into their forward and backward running components

F Pythoud1, N Stergiopulos, J J Meister

  • 1Biomedical Engineering Laboratory, Swiss Federal Institute of Technology, Lausanne, Switzerland.

Related Concept Videos

Sound as Pressure Waves01:17

Sound as Pressure Waves

Sound waves, which are longitudinal waves, can be modeled as the displacement amplitude varying as a function of the spatial and temporal coordinates. As a column of the medium is displaced, its successive columns are also displaced. As the successive displacements differ relatively, a pressure difference with the surrounding pressure is created. The gauge pressure varies across the medium.
The pressure fluctuation depends on the difference in displacements between the successive points in the...
4.7K
Korotkoff Sounds01:12

Korotkoff Sounds

Korotkoff sounds are the specific sounds heard while measuring blood pressure using a sphygmomanometer, typically with a stethoscope or a Doppler device. They are named after Russian physician Nikolai Korotkov, who first described them in 1905. These sounds correspond to turbulent blood flow in the artery as the blood pressure cuff is gradually released after inflation.
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
9.6K
Traveling Waves: Lossless Lines01:27

Traveling Waves: Lossless Lines

The provided content explores the behavior of traveling waves on single-phase lossless transmission lines. It begins with a single-phase two-wire lossless transmission line of length Δx, characterized by a loop inductance LH/m and a line-to-line capacitance C F/m. These parameters result in a series inductance LΔx  and a shunt capacitance CΔx.
503
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
1.8K
Pulse01:16

Pulse

When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
2.4K
Pressure Variation in a Fluid at Rest01:11

Pressure Variation in a Fluid at Rest

In a fluid at rest, the pressure at any point beneath the fluid surface depends solely on the depth, not on the container's shape or size. This principle, known as hydrostatic pressure, arises because, in stationary fluids, there is no acceleration, meaning the forces within the fluid balance out. Only vertical forces, caused by the weight of the fluid above, contribute to pressure changes with depth.
When measuring pressure at two different levels within the fluid, the difference in...
897