Related Experiment Video
Updated: Mar 2, 2026

Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Separation of arterial pressure waves into their forward and backward running components
F Pythoud1, N Stergiopulos, J J Meister
1Biomedical Engineering Laboratory, Swiss Federal Institute of Technology, Lausanne, Switzerland.
Abstract:
A new separation technique has been developed to determine the forward and backward running arterial pressure wave components. It takes into account friction as well as nonlinear effects due to convective acceleration and to the pressure dependence of the arterial compliance. The new method is a combination of two methods treating friction and nonlinearities separately. The method requires the measurements of pressure and flow at one location as well as the knowledge of the area-pressure relationship. The validity of the method was tested by a simulation experiment in which the forward and backward waves were known a priori. It was shown that the new method is significantly more accurate in the predictions of the forward and backward waves when compared to the classical method assuming linearity and no dissipation. The new wave separation method was also applied to simulated aortic waves for (a) a healthy subject and (b) a subject with decreased compliance. Comparison with the classical linear method showed that neglecting nonlinearities leads to an overestimation of the forward and backward pressure wave amplitudes. The errors, however, were in the order of 5 to 10 percent. We concluded that, for most clinical purposes, the improvement using the nonlinear method is of the same magnitude as experimental errors, and thus the linear method would suffice.
More Related Videos
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
06:08Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Related Concept Videos
Sound as Pressure Waves
The pressure fluctuation depends on the difference in displacements between the successive points in the...
Korotkoff Sounds
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
Traveling Waves: Lossless Lines
Assessment of blood pressure in brachial artery(two-step method)
Pulse
The pulse serves as a clinical...
Pressure Variation in a Fluid at Rest
When measuring pressure at two different levels within the fluid, the difference in...