Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
Measurement of blood pressure may be affected by an interaction between subject and observer based on gender
1University Department of Medicine, Royal Perth Hospital, Western Australia.
Abstract:
Retrospective studies have suggested that blood pressure (BP) may be affected by a covert gender interaction between patient and observer, which is most marked for female patients and male observers. Such an effect could be one of the determinants of the "white coat' response. We have assessed this interaction in a prospective study in 56 hospital outpatients (31 males, 25 females) in whom supine and erect BP and heart rate were measured by two male and two female subjects, and by an automatic sphygmomanometer when no persons were present. Supine systolic BP (SBP) was related to age, and fell progressively over three measurements. Absolute BP was less in females but the fall on repeated measurement was significantly greater than in males. When absolute BP was analysed by patient and observer sex, no significant interaction was present. BP measured by automatic sphygmomanometry was less than the value obtained clinically. Absolute BP showed no significant interaction with observer and patient sex, but the difference between machine and age-adjusted clinical measurements for SBP was significantly greater in female patients when BP was measured by male observers. However, this effect dissipated on repeated measurement. These data suggest that a transient gender interaction can contribute to the white-coat effect, especially in female patients when BP is measured by a male observer.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure