Related Experiment Video
Updated: Aug 6, 2026

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Mobile mammography: results of a national survey
N D DeBruhl1, L W Bassett, N W Jessop
1Iris Cantor Center for Breast Imaging, Department of Radiological Sciences, UCLA School of Medicine, Los Angeles, CA 90095-6952, USA.
Purpose:
to learn about mobile mammography in the United States.
Materials And Methods:
A survey of 82 questions was designed, pilot tested, and sent to mobile mammography facilities. The questions addressed many aspects of mobile programs, including administrative, financial, equipment, personnel, film processing, quality assurance, and communication of results.
Results:
Of the 367 facilities that were mailed surveys, 159 facilities completed the survey, and 30 (19%) of those had discontinued their mobile programs. Seventy-six of 158 (48%) mobile facilities had performed mobile mammography for 1-5 years, and 69 of 158 (44%) had performed mobile mammography for more than 5 years. Seventy-two of 156 (46%) facilities were hospital-owned, and 25 of 156 (16%) were radiologist-owned. One hundred seven of 159 (67%) mobile facilities performed screening only. One hundred fourteen of 152 (75%) facilities charged +80.00 or less for screening. Mobile facilities averaged 20 examinations per day and served diverse populations. Sixty-seven of 159 (42%) facilities accepted self-referred women. Thirty-one percent of the facilities performed on-board processing. Only 71 of 149 (47%) facilities were financially profitable or breaking even, but 112 of 154 (73%) facilities would undertake a mobile project again.
Conclusion:
Mobile programs provide an opportunity to increase access to screening mammography, but they face many obstacles.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...

