A safe clinical system for nitric oxide inhalation therapy for pediatric patients
Related Experiment Video
Updated: Nov 3, 2026

A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
K Miyasaka1, H Fujiwara, M Takata
1Department of Anesthesia and ICU, National Children's Hospital, Tokyo, Japan.
Abstract:
A safe clinical system for nitric oxide (NO) inhalation therapy was developed. The system consists of three parts: a NO controller, a NO monitor, and a patient circuit. NO gas flow and carrier gas flow are controlled by a special rust-proof thermal mass flowmeter. Standard gas quality NO gas (10,000 ppm, balance nitrogen) is used. The outlet of the NO gas tank is connected to the distal end of a heated humidifer that is very close (12 mL) to the patient, to decrease acidic water precipitation and decrease contact time between NO and oxygen (O2). Fail-safe mechanisms to prevent the delivery of a hypoxic mixture or excessive NO concentration are incorporated. Inspiratory NO concentration is continuously monitored by a modified electrochemical NO meter. The patient circuit consists of a breathing circuit and a ventilator with a scavenging unit. A modified Mapleson D type circuit is used. Fresh gas, humidified and mixed with NO, is introduced to the patient connection port. A mechanical ventilator, either of conventional or of high-frequency oscillation type, is connected to the expiratory limb of the Mapleson D circuit. A coaxial scavenging unit including activated charcoal is placed in between the expiratory limb and the ventilator. The adjustment of inspiratory NO concentration (y) was accurate over a wide range (1-80 ppm) of concentrations (x) (y = 0.36 + 0.96x, R2 = 0.999, n = 45) and showed good agreement with the chemiluminescence method. Inspiratory nitrous oxide (NO2) concentration was less than 0.3 ppm, and acidic water accumulation as measured by NO2- and NO3- was less than 5 ppm, even at an extremely high NO concentration of 80 ppm with an FiO2 of 1.0 and 10 L/min of fresh gas flow. Environmental NO and NO2 concentrations in the ICU remained below 0.005 and 0.05 ppm, respectively. This system was used clinically on 214 pediatric patients and proved to be accurate, safe, and useful.
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Inhalational Anesthetics: Overview
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: