Problems and practical considerations in assessing accuracy with NIST SRM 909a: report of defective vials
Abstract:
During an experimental period of 12 months in 1992-1993, while we were comparing the effectiveness of monthly vs quarterly use of the National Institute for Standards and Technology Standard Reference Material (NIST SRM) 909a as an accuracy material for the projected 30-year Fernald Medical Monitoring Program, we encountered three random defective vials with a glucose recovery of less than 30% of the NIST-assigned value. Analysis with five different multichannel instruments confirmed the original finding. Concomitant glucose recovery from adjacent vials was 97%-104%, as determined by using the same instruments, reagents, calibrators, and quality-control criteria on the same days. Recoveries of uric acid and cholesterol were also low (53-75% and 75-80%, respectively) in the three defective vials. Other analytes were unaffected. Studies to identify the cause of the defective vials were carried out with microbiological, electron microscopic, and biochemical techniques. When used for accuracy studies, each vial of NIST SRM 909a should have a concomitant check for glucose recovery to detect whether the vial is defective.
More Related Videos
Related Concept Videos
Random and Systematic Errors
Testing a Claim about Standard Deviation
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Data Validation
Key parameters for method validation include:
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Automated Microbial Diagnostics