Evaluation of dynamic performance in liquid-filled catheter systems for measuring invasive blood pressure
M Todorovic1, E W Jensen, C Thøgersen
1Department of Anaesthesia and Intensive Care, Odense University Hospital, Denmark.
Abstract:
Invasive blood pressure measurement is used in patients with unstable haemodynamics. The demand of the accuracy of these measurements is high. The reliability of the reproduced signal strongly depends on the measurement system's dynamic characteristic-its resonance frequency and damping factor. These characteristics were examined with the frequency response method, which is valuable for second and higher order systems. Most of the pressure measuring systems in use in clinical practice have low damping factor (0.1-0.2), which causes high overshoot in systolic pressure values (up to 13%), since putting all the measuring components in a chain reduces the dynamic properties of a single component and the resonance frequency drops drastically from over 100 Hz to even below 10 Hz. One of the solutions to increase the damping ratio is to insert a damping device R.O.S.E. parallel to the tubing. The resonance frequency remains the same, the damping factor increases to around 0.5. Systems with higher damping factors (0.5-0.7) have lower overshoot (1-2%), therefore the blood pressure measurements are more accurate.
More Related Videos
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure