Related Experiment Video
Updated: Aug 13, 2026

F1FO ATPase Vesicle Preparation and Technique for Performing Patch Clamp Recordings of Submitochondrial Vesicle Membranes
Published on: May 4, 2013
Na+,K(+)-ATPase pump currents in giant excised patches activated by an ATP concentration jump
T Friedrich1, E Bamberg, G Nagel
1Max-Planck-Institut für Biophysik, Frankfurt am Main, Germany.
Abstract:
The giant-patch technique was used to study the Na+,K(+)-ATPase in excised patches from rat or guinea pig ventricular myocytes. Na+,K(+)-pump currents showed a saturable ATP dependence with aK(m) of approximately 150 microM at 24 degrees C. The pump current can be completely abolished by ortho-vanadate. Dissociation of vanadate from the enzyme in the absence of extracellular Na+ was slow, with a Koff of 3.10(-4) S-1 (K1 approximately 0.5 microM, at 24 degrees C). Stationary currents were markedly dependent on intracellular pH, with a maximum at pH 7.9. Temperature-dependence measurements of the stationary pump current yielded an activation energy of approximately 100 kJ mol-1. Partial reactions in the transport cycle were investigated by generating ATP concentration jumps through photolytic release of ATP from caged ATP at pH 7.4 and 6.3. Transient outward currents were obtained at pH 6.3 with a fast rising phase followed by a slower decay to a stationary current. It was concluded that the fast rate constant of approximately 200 s-1 at 24 degrees C (pH 6.3) reflects a step rate-limiting the electrogenic Na+ release. Simulating the data with a simple three-state model enabled us to estimate the turnover rate under saturating substrate concentrations, yielding rates (at pH 7.4) of approximately 60 s-1 and 200 s-1 at 24 degrees C and 36 degrees C, respectively.
More Related Videos
11:42Reconstitution of a Transmembrane Protein, the Voltage-gated Ion Channel, KvAP, into Giant Unilamellar Vesicles for Microscopy and Patch Clamp Studies
Published on: January 22, 2015
08:34Contribution of the Na+/K+ Pump to Rhythmic Bursting, Explored with Modeling and Dynamic Clamp Analyses
Published on: May 9, 2021
Related Concept Videos
Action Potentials
ATP Driven Pumps I: An Overview
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and are...
ATP Synthase: Structure
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...