Related Experiment Videos
Tensile fatigue strength of light cure composite resins for posterior teeth
1Department of Oral Diagnosis and General Dentistry, Faculty of Dentistry, Tokyo Medical and Dental University, Japan.
Abstract:
The fatigue property of the composite resin has recently been a subject of research. In this study, the fatigue strength and the tensile strength of composite resins stored in water were investigated. Two types of light cure composite resins were used: a Hybrid type and am MFR type. Dumbbell-shaped specimens were prepared. After storage at 37 +/- 0.5 degrees C for 24 hours, 1 month, 3 months, 6 months and 12 months, the fatigue test and the direct tensile test were performed. The staircase method was employed to analyze the fatigue strength under a 10(5) cyclic load. The fatigue strength of the Hybrid type at 24h ours was 54.7 MPa; that of the MFR type was 28.1 MPa. Both fatigue strengths decreased during water storage. Otherwise, the tensile strength of the Hybrid type was 77.0 MPa; that of the MFR type was 53.5 MPa. After 12 months of storage, the tensile strength of the Hybrid type remained unchanged during water storage; however, that of the MFR type decreased.