Related Experiment Videos
Use of a mechanical simulator for training in applying cricoid pressure
N Ashurst1, C C Rout, D A Rocke
1Department of Anaesthetics, University of Natal, Durban, South Africa.
British Journal of Anaesthesia
|October 1, 1996
Summary
Untrained anesthesia personnel often apply inadequate cricoid force, risking patient aspiration. A brief training program improved cricoid force application and retention for up to three weeks.
Area of Science:
- Anesthesiology
- Airway Management
- Medical Education
Background:
- Cricoid force application is crucial in airway management to prevent aspiration.
- Previous studies indicate variability and inadequacy in cricoid pressure application by healthcare professionals.
- The effectiveness of training interventions on cricoid force application skills requires further investigation.
Purpose of the Study:
- To assess the accuracy of cricoid force application by anesthesia personnel.
- To evaluate the impact of a short training program on cricoid force application skills.
- To determine the retention of cricoid force application skills over time.
Main Methods:
- Utilized an airway management training model with a hydraulic perspex device to measure cricoid pressure.
- Assessed 49 anesthesia assistants and anesthetists on cricoid force application at 20 N and 40 N.
- Provided training over 3 consecutive days with reassessment at 14-21 days for 18 participants.
Main Results:
- Initially, 63% of participants applied inadequate cricoid force with significant variation.
- A single training session markedly improved cricoid force application, with no further gains from additional sessions.
- Skill retention was observed in 72% of participants at 14-21 days, though initial inadequacy predicted later performance.
- Participants often applied excessive initial force with a subsequent decrease, a trend improved by training.
Conclusions:
- The majority of untrained anesthesia personnel apply inadequate cricoid force, posing an aspiration risk.
- A simple training program effectively improves cricoid force application and skill retention for at least three weeks.
- Despite training, a decrease in applied force during a single application was noted, highlighting the need for ongoing reinforcement.