An integrated system for measuring static and dynamic accommodation with a Canon Autoref R-1 refractometer

P A Wetzel1, G A Geri, B J Pierce

  • 1Hughes Training Inc., Mesa, AZ 85206, USA.

Ophthalmic & Physiological Optics : the Journal of the British College of Ophthalmic Opticians (Optometrists)
|November 1, 1996
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The role of visual occlusion in altitude maintenance during simulated flight.

Journal of experimental psychology. Human perception and performance·2008
Same author

Predictors of nutritive sucking in preterm infants.

Journal of perinatology : official journal of the California Perinatal Association·2006
Same author

Discrimination of wide-field images as a test of a peripheral-vision model.

Journal of the Optical Society of America. A, Optics, image science, and vision·2001
Same author

Types of shear disparity and the perception of surface inclination.

Perception·1998
Same author

Depth interactions between inclined and slanted surfaces in vertical and horizontal orientations.

Perception·1998
Same author

Theoretical considerations concerning the effect of relativistic velocities on the rate of biological processes.

Aviation, space, and environmental medicine·1998
Same journal

Mesopic Illumination in Natural Environments: Implications for Myopia Research.

Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)·2026
Same journal

Axial Length Growth Reference Curves and LMS Parameters for Japanese Children and Adolescents Aged 4-20 Years: The TMM BirThree Cohort Study.

Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)·2026
Same journal

Effect of Switching Myopia Control Strategies on Axial Elongation in Children with Poor Response to Highly Aspherical Lenslet Therapy.

Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)·2026
Same journal

Quantifying the Role of Longitudinal Chromatic Aberration and Age in Night Vision Disturbances.

Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)·2026
Same journal

Impaired Rod-Mediated Vision is the Functional Hallmark of Ageing and Early and Intermediate Age-Related Macular Degeneration.

Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)·2026
Same journal

Analytical Performance, Spatial Dynamics and Clinically Meaningful Change Thresholds for Automated Non-invasive Tear Film Assessment Using the Oculus Keratograph 5M.

Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)·2026
See all related articles

This study introduces an integrated system for collecting and analyzing static and dynamic accommodation data. The system enhances the Canon Autoref R-1 refractometer with hardware and software for efficient data measurement and processing.

Area of Science:

  • Ophthalmology
  • Optometry
  • Vision Science

Background:

  • Accurate measurement of ocular accommodation is crucial for understanding visual function.
  • Existing methods for collecting accommodation data can be inefficient or lack comprehensive analysis capabilities.
  • The Canon Autoref R-1 refractometer offers potential for accommodation measurement, but requires system integration.

Purpose of the Study:

  • To describe an integrated system for efficient collection and analysis of static and dynamic accommodation data.
  • To detail hardware modifications and software developed for the Canon Autoref R-1.
  • To highlight specific features of the Canon R-1 relevant to accommodation measurement.

Main Methods:

  • Integration of hardware modifications with the Canon Autoref R-1 refractometer.

Related Experiment Videos

  • Development of custom software (Microsoft C/C++ under DOS) for data acquisition and processing.
  • Utilizing the Canon Autoref R-1 for both static and dynamic accommodation measurements.
  • Main Results:

    • An efficient system for collecting and analyzing accommodation data was successfully developed.
    • The integrated system facilitates comprehensive measurement and processing of visual accommodation.
    • The system leverages specific, often unapparent, features of the Canon Autoref R-1.

    Conclusions:

    • The described integrated system provides an efficient method for studying ocular accommodation.
    • The hardware and software enhancements improve data collection and analysis capabilities for the Canon Autoref R-1.
    • This system offers a valuable tool for researchers and clinicians investigating visual accommodation.