Related Experiment Video
Updated: Aug 16, 2026

Ex Vivo Assessment of Contractility, Fatigability and Alternans in Isolated Skeletal Muscles
Published on: November 1, 2012
Sympathetic influences on electrical and mechanical alternans in the canine heart
D E Euler1, H Guo, B Olshansky
1Department of Medicine, Loyola University Medical Center, Maywood, IL 60153, USA.
Objective:
The aim was to investigate the influence of the sympathetic nervous system on the induction of mechanical and electrical alternans in the intact canine heart.
Methods:
Experiments were performed on 8 open-chest dogs anesthetized with sodium pentobarbital. A micromanometer-tipped catheter was used to measure left ventricular pressure, dp/dt and the time constant of isovolumic relaxation. Rapid atrial pacing was used to induce alternans and the left stellate ganglion was stimulated electrically to alter sympathetic tone. The longest pacing cycle length that showed a significant alternation in peak systolic pressure was defined as the alternans threshold. Electrical alternans was detected by comparing the ST-T area in the surface ECG (lead II) on alternate beats.
Results:
The alternans threshold was 305(s.e.m. 10.4) ms under control conditions and decreased to 271(12.1), 225(33.4), and 177(6.2)ms, as the frequency of left stellate stimulation was increased to 1, 2, and 5 Hz, respectively (P < 0.001). Tau and peak -dp/dt began to alternate at the same pacing cycle length as peak +dp/dt and peak systolic pressure. Electrical alternans was only observed during mechanical alternans and the ST-T area of the strong beat was 243(143)% greater than the ST-T area of the weak beat (P < 0.001). Timolol (1 mg.kg-1) blocked the effect of left stellate stimulation (1 and 2 Hz) on mechanical and electrical alternans.
Conclusions:
Left sympathetic activation causes a frequency-dependent reduction in the threshold cycle length for global mechanical and electrical alternans. Alternation in relaxation occurs at the same pacing cycle length as does alternation in contraction. Repolarization alternans in the surface ECG appears to reflect underlying mechanical events.
More Related Videos
09:26Optical Mapping of Intra-Sarcoplasmic Reticulum Ca2+ and Transmembrane Potential in the Langendorff-perfused Rabbit Heart
Published on: September 10, 2015
09:20Microelectrode Array Recording of Sinoatrial Node Firing Rate to Identify Intrinsic Cardiac Pacemaking Defects in Mice
Published on: July 5, 2021
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Mechanism of Cardiac Arrhythmias
Pathophysiology of Cardiac Performance
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Heart Failure II: Pathophysiology