Optimum parameters for short-wavelength automated perimetry

P A Sample1, C A Johnson, G Haegerstrom-Portnoy

  • 1Department of Ophthalmology, University of California, San Diego, La Jolla.

Journal of Glaucoma
|December 1, 1996
PubMed
Summary

Standardizing short-wavelength automated perimetry (SWAP) requires specific parameters. A yellow background with a blue stimulus optimizes SWAP for better clinical use and data comparison.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A multi-estuary assessment of pharmaceutical exposure and risk of pharmacological effects in a recreational fishery.

Environmental toxicology and chemistry·2025
Same author

Widespread pharmaceutical exposure at concentrations of concern for a subtropical coastal fishery: Bonefish (Albula vulpes).

Marine pollution bulletin·2024
Same author

Differential tissue distribution of pharmaceuticals in a wild subtropical marine fish.

Aquatic toxicology (Amsterdam, Netherlands)·2024
Same author

Identifying pathways of pharmaceutical exposure in a mesoconsumer marine fish.

Journal of hazardous materials·2024
Same author

From eDNA to decisions using a multi-method approach to restoration planning in streams.

Scientific reports·2024
Same author

Chytrid infections exhibit historical spread and contemporary seasonality in a declining stream-breeding frog.

Royal Society open science·2024

Area of Science:

  • Ophthalmology
  • Visual Science
  • Perimetry

Background:

  • Short-wavelength automated perimetry (SWAP) is a visual field test.
  • Standardization is needed for reliable clinical comparisons.

Purpose of the Study:

  • Determine optimal parameters for SWAP.
  • Recommend these parameters for procedural standardization.

Main Methods:

  • Evaluated various stimulus and background configurations.
  • Measured threshold versus intensity curves.
  • Assessed effects of lens absorption and cataract.

Main Results:

  • Optimal parameters: 100 cd/m2 broad-band yellow background.
  • Optimal stimulus: 440-nm, 1.8-degree diameter, 200 ms duration.

Related Experiment Videos

  • Recommendations provided for modifying existing perimeters.
  • Conclusions:

    • Agreement on SWAP parameters will enable test standardization.
    • Facilitates comparison of results across different centers.