O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
Genetic algorithm-based method for selecting wavelengths and model size for use with partial least-squares
A S Bangalore1, R E Shaffer, G W Small
1Department of Chemistry, Clippinger Laboratories, Ohio University, Athens 45701-2979, USA.
Abstract:
Genetic algorithms (GAs) are used to implement an automated wavelength selection procedure for use in building multivariate calibration models based on partial least-squares regression. The method also allows the number of latent variables used in constructing the calibration models to be optimized along with the selection of the wavelengths. The data used to test this methodology are derived from the determination of aqueous organic species by near-infrared spectroscopy. The three data sets employed focus on the determination of (1) methyl isobutyl ketone in water over the range of 1-160 ppm, (2) physiological levels of glucose in a phosphate buffer matrix containing bovine serum albumin and triacetin, and (3) glucose in a human serum matrix. These data sets feature analyte signals near the limit of detection and the presence of significant spectral interferences. Studies are performed to characterize the signal and noise characteristics of the spectral data, and optimal configurations for the GA are found for each data set through experimental design techniques. Despite the complexity of the spectral data, the GA procedure is found to perform well, leading to calibration models that significantly outperform those based on full spectrum analyses. In addition, a significant reduction in the number of spectral points required to build the models is realized.
Related Concept Videos
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to the...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...