Related Experiment Video
Updated: Oct 6, 2026

Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
Exponentially tapered T-tube model in the characterization of arterial non-uniformity
1Department of Physiology, College of Medicine, National Taiwan University, Taipei.
Abstract:
There is no question that geometric and elastic tapering is the rule of the nature of the mammalian arterial system. In this investigation, we determine the role of an exponentially tapered T-tube model to characterize the non-uniform nature and physical properties of the vasculature. The tapering feature could be inferred to show a connection between characteristic impedance at the distal of the tube and that at the entrance of the tube. Pulsatile pressure and flow signals of the ascending aorta were measured in 12 closed-chest, anesthetized dogs. This non-uniform T-tube model fits the measured aortic pressure waveform well. The mathematical and experimental model impedance spectra are similar. In the basal state, the distal characteristic impedance is 9.5% higher than the input characteristic impedance. The input characteristic impedance estimated in the model is compatible with that calculated by averaging high-frequency moduli of impedance data points obtained from the ratio of the corresponding harmonics of pressure and flow. Furthermore, the exponentially tapered T-tube model has a close estimate in wave transit time when compared with that computed by the impulse response of the filtered aortic input impedance. These data suggest that inclusion of tube tapering improves the mathematical model so that it is capable of characterizing the non-uniform nature of the arterial system. We conclude that the non-uniform properties of wave-transmission paths play an important role in governing the behavior of an asymmetric T-tube for the representation of the arterial system.
More Related Videos
06:34Finite Element Modeling for the Simulation of the Quasi-Static Compression of Corrugated Tapered Tubes
Published on: January 6, 2023
06:18Intravascular Ultrasound Image-Based Finite Element Modeling Approach for Quantifying In Vivo Mechanical Properties of Human Coronary Artery
Published on: December 6, 2024
Related Concept Videos
Three-Compartment Open Model
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models
Bernoulli's Equation for Flow Normal to a Streamline
The pressure difference depends on the fluid's velocity and radius of curvature. The pressure variation is minimal in flows with nearly straight streamlines. However, the...
Steady, Laminar Flow in Circular Tubes
Typical Model Studies
General Characteristics of Pipe Flow II
The distance to reach a fully developed flow is called the entrance length and depends on the flow...