Analysis of long-lived radionuclidic impurities in short-lived radiopharmaceutical waste using gamma spectrometry
Related Experiment Video
Updated: Oct 20, 2026
![An Automated Radiosynthesis of [68Ga]Ga-FAPI-46 for Routine Clinical Use](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F66708.jpg&w=3840&q=50)
An Automated Radiosynthesis of [68Ga]Ga-FAPI-46 for Routine Clinical Use
Published on: May 24, 2024
1Molecular Cancer Institute, University of California, Davis, Sacramento 95816, USA.
Abstract:
Large hospitals and biomedical research centers utilize decay-in-storage programs to minimize the volume of their low level radioactive waste. However, some medically useful radionuclides often contain small amounts of long-lived radionuclidic impurities which may complicate simple waste management procedures. We have evaluated the extent of this problem in low level radioactive waste involving 67Cu and (111)In over a 6-mo cycle of decay-in-storage by identifying the residual radionuclides in our dry waste using a multichannel analyzer. The multichannel analyzer was also used to quantify the radionuclide constituents of our liquid waste at the beginning of a decay-in-storage cycle. Radionuclides were identified by the presence of characteristic photopeaks of each isotope in the gamma spectrum and quantified by region of interest analysis. After a decay-in-storage cycle, long-lived 58Co, 57Co, and 56Co isotopes were observed in dry 67Cu waste and (114m)In identified in dry (111)In waste. The (114m)In was detected in dry (111)In waste containing initial (114m)In activity of 740 kBq (20 microCi), while the cobalt radionuclides were detected in dry 67Cu waste containing initial 58Co, 57Co, and 56Co activities of 444, 148, and 148 kBq (12, 4, and 4 microCi), respectively. Such dry low level radioactive waste was thus disqualified from short-term radioactive waste storage programs. The radionuclide constituents in the liquid waste were quantified in microCi mL(-1) and confirmed to be within the Nuclear Regulatory Commission set limits of 2 x 10(-4), 6 x 10(-4) and 6 x 10(-5) microCi mL(-1) for 58Co, 57Co, and 56Co, respectively, before disposal. The highest levels of long-lived isotopes that have been found in our liquid low level radioactive waste at the beginning of decay-in-storage were 5.5 x 10(-4), 4.8 x 10(-4), and 1.4 x 10(-4) microCi mL(-1) for 58Co, 57Co, and 56Co, respectively. Gamma spectrometry can be used to aid waste segregation and final management decisions on low level radioactive waste.
More Related Videos
Related Concept Videos
Radioactive Decay and Radiometric Dating
Isotopes and Radioisotopes
An isotope containing more...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

![Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F68356.jpg&w=3840&q=50)