The noise level in magnetic stimulation

J Starck1, I Rimpiläinen, I Pyykkö

  • 1Finnish Institute of Occupational Health, Department of Physics, Vantaa, Finland.

Scandinavian Audiology
|January 1, 1996
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Safe management of full-capacity live/mass events in COVID-19 will require mathematical, epidemiological and economic modelling.

Journal of the Royal Society of Medicine·2021
Same author

Imaging of Temporal Bone.

Advances in oto-rhino-laryngology·2019
Same author

An epigenome-wide association study meta-analysis of educational attainment.

Molecular psychiatry·2017
Same author

Genetic risk scores and family history as predictors of schizophrenia in Nordic registers.

Psychological medicine·2017
Same author

Genome-wide association study of lifetime cannabis use based on a large meta-analytic sample of 32 330 subjects from the International Cannabis Consortium.

Translational psychiatry·2016
Same author

The association between lower educational attainment and depression owing to shared genetic effects? Results in ~25,000 subjects.

Molecular psychiatry·2015
Same journal

Vision and hearing in old age.

Scandinavian audiology·2002
Same journal

Two families with phenotypically different hereditary low frequency hearing impairment: longitudinal data and linkage analysis.

Scandinavian audiology·2002
Same journal

Age and noise-induced hearing loss.

Scandinavian audiology·2002
Same journal

Bilateral hearing aids--effects and consequences from a user perspective.

Scandinavian audiology·2002
Same journal

Threshold-based fitting methods for non-linear (WDRC) hearing instruments--comparison of acoustic characteristics.

Scandinavian audiology·2002
Same journal

Will hearing healthcare be affordable in the new millennium.

Scandinavian audiology·2001
See all related articles

Magnetic stimulator coils produce impulse noise that may affect hearing. However, the risk to patients and examiners is considered small, especially with hearing protection.

Area of Science:

  • Neuroscience
  • Audiology
  • Biomedical Engineering

Background:

  • Stimulating coils in magnetic stimulation devices generate impulse noise.
  • This noise poses a potential risk to the hearing of both patients and examiners.
  • Understanding the sound pressure levels is crucial for assessing audiological safety.

Purpose of the Study:

  • To evaluate the potential hearing risk from impulse noise of magnetic stimulator coils.
  • To measure A-weighted peak sound pressure levels (SPL) from different magnetic stimulator coils.
  • To compare measured SPLs against established occupational noise exposure limits.

Main Methods:

  • Measured A-weighted peak sound pressure levels (SPL) from five different magnetic stimulator coils.
  • Tested coils at 100% stimulation intensity and distances of 10 cm and 40 cm.

Related Experiment Videos

  • Calculated potential daily exposure based on American Conference of Governmental Industrial Hygienists (ACGIH) guidelines.
  • Main Results:

    • Peak SPLs at 10 cm ranged from 110 dB (Dantec, Magstim) to 132 dB (Cadwell MES-10).
    • Sound levels decreased with distance, closely following the inverse square law (average 14 dB decrease at 40 cm).
    • Calculated daily allowable stimuli (1000-10,000) suggest exceeding limits is unlikely in typical clinical settings.

    Conclusions:

    • The risk of hearing damage from magnetic stimulator coil noise is considered small for patients and operators.
    • Hearing protection, even lightweight, can further mitigate potential risks.
    • Adherence to safety guidelines and use of protective measures are recommended.