Automatic end-tidal gas sampling system for non-invasive rCBF measurements

H M Shapiro, J E Inacker, W D Obrist

    Stroke
    |July 1, 1977
    PubMed
    Summary

    This study introduces an automated system for measuring xenon-133 (133Xe) in exhaled breath. This system accurately estimates arterial 133Xe concentrations for non-invasive cerebral blood flow measurements in various patient types.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Cerebral Blood Flow and Metabolism after Intracranial Trauma.

    Progress in neurological surgery·2016
    Same author

    2',7'-bis-(Carboxyethyl)-5-(6')-Caroboxyfluorescein (BCECF) as a probe for intracellular fluorescence polarization measurements.

    Journal of biomedical optics·2012
    Same author

    Laser beam shaping and spot size.

    Current protocols in cytometry·2008
    Same author

    Falling estradiol levels as a result of intentional reduction in gonadotrophin dose are not associated with poor IVF outcomes, whereas spontaneously falling estradiol levels result in low clinical pregnancy rates.

    Human reproduction (Oxford, England)·2004
    Same author

    Microbiology.

    Clinics in laboratory medicine·2002
    Same author

    Violet laser diodes as light sources for cytometry.

    Cytometry·2001

    Area of Science:

    • Medical Imaging and Diagnostics
    • Neuroscience
    • Respiratory Physiology

    Background:

    • Non-invasive regional cerebral blood flow (rCBF) measurement using 133Xe requires accurate arterial 133Xe concentration data.
    • Arterial 133Xe levels are typically estimated from end-tidal breath concentrations.
    • Existing methods for end-tidal sampling may lack automation and versatility.

    Purpose of the Study:

    • To describe and evaluate an automated sampling system for measuring end-tidal 133Xe concentrations.
    • To assess the system's utility in both spontaneously breathing and mechanically ventilated patients.
    • To compare the automated system's performance against manual measurement techniques.

    Main Methods:

    • Development of an automated gas sampling system for end-tidal 133Xe measurement.

    Related Experiment Videos

  • Testing the system on spontaneously breathing and mechanically ventilated patients.
  • Comparative analysis of automated sampling versus manual measurement from a continuous gas sample.
  • Main Results:

    • The automated system provides a reliable method for measuring end-tidal 133Xe concentrations.
    • The system is applicable across different patient ventilation modes.
    • Performance comparison demonstrated the accuracy and efficiency of the automated approach.

    Conclusions:

    • The automated sampling system offers an improved method for obtaining arterial 133Xe concentrations for rCBF studies.
    • This technology enhances the non-invasive assessment of cerebral blood flow.
    • The system supports accurate physiological measurements in critical care settings.