Use of a pneumatic tourniquet induces changes in central temperature
J P Estebe1, A Le Naoures, Y Malledant
1Département d'Anesthésie Réanimation Chirurgical, Centre Hospitalier Régional, Rennes, France.
Pneumatic tourniquet use during orthopaedic surgery can increase core body temperature, especially with active warming. Temperature changes were observed in oesophageal and rectal monitoring, with a transient decrease after tourniquet removal.
Area of Science:
- Anesthesiology and Perioperative Medicine
- Orthopaedic Surgery
- Thermoregulation
Background:
- Maintaining stable core body temperature is crucial during surgical procedures.
- Pneumatic tourniquets are commonly used in orthopaedic surgery, but their effect on patient thermoregulation is not fully understood.
Purpose of the Study:
- To investigate the impact of pneumatic tourniquet use on core body temperature during orthopaedic surgery.
- To compare the effects of passive insulation versus active forced-air warming in patients undergoing tourniquet application.
Main Methods:
- Twenty-six patients undergoing orthopaedic surgery were monitored for oesophageal and rectal temperature.
- Twenty patients received a pneumatic tourniquet and were divided into a passive insulation group (Pg) and a forced-air warming group (Fg).
- Six patients without a tourniquet served as a reference group (Rg).
Main Results:
- Oesophageal temperature increased significantly during tourniquet inflation compared to the reference group.
- Active forced-air warming (Fg) resulted in significantly higher oesophageal temperatures than passive insulation (Pg) after 30 minutes.
- Rectal temperature changes mirrored oesophageal trends but were significantly delayed.
Conclusions:
- Pneumatic tourniquet use is associated with an increase in core body temperature during orthopaedic surgery.
- Active forced-air warming enhances this temperature increase compared to passive insulation.
- The observed decrease in temperature post-deflation may be due to blood redistribution from a cooled limb.
Related Concept Videos
Decreased Body Temperature
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...