Related Experiment Videos
Argon beam coagulation rescue to correct bleeding during pelviscopy
D I Galen1, A Jacobson, L N Weckstein
15601 Norris Canyon Road, Suite 300, San Ramon, CA 94583, USA.
Abstract:
A new technique of unipolar laparoscopic coagulation is particularly useful for the treatment of pelvic or abdominal bleeding during laparoscopic procedures. Blood present at the coagulation site is blown clear with a stream of argon gas prior to tissue coagulation. Of particular importance is the virtual absence of smoke, and because the procedure involves a nontouch technique, eschar is not removed inadvertently. The speed of tissue coagulation is faster than that of conventional bipolar and unipolar techniques.