Related Experiment Video
Updated: Sep 11, 2026

High-Resolution Endocardial and Epicardial Optical Mapping in a Sheep Model of Stretch-Induced Atrial Fibrillation
Published on: July 29, 2011
Configuration of unipolar atrial electrograms during electrically induced atrial fibrillation in humans
K T Konings1, J L Smeets, O C Penn
1Department of Physiology, Cardiology and Cardiopulmonary Surgery, Cardiovascular Research Institute Maastricht, Maastricht University, The Netherlands.
Background:
During atrial fibrillation (AF), the atrium is activated by multiple wavelets that continuously change in size and direction. The aim of this study was to correlate the temporal variation in AF electrogram configuration with the varying spatial patterns of activation.
Methods And Results:
In a group of 25 Wolff-Parkinson-White patients undergoing cardiac surgery, the free wall of the right atrium was mapped (244 points) during electrically induced AF. The unipolar electrograms recorded during 4 seconds of AF were classified into four categories: (1) single deflections, (2) short-double potentials, (3) long-double potentials, and (4) fragmented potentials. The proportion of these four types of electrograms during AF was as follows: singles, 77 +/- 12%; short-doubles, 7 +/- 3%; long-doubles, 10 +/- 7%; and fragmented, 6 +/- 4%. Electrogram morphology was an indicator for rapid uniform conduction (single potentials; positive predictive value [PPV] of 0.96), collision (short-double potentials; PPV of 0.33), conduction block (long-double potentials; PPV of 0.84), and pivoting points or slow conduction (fragmented potentials; PPV of 0.87). In type I, II, and III AF, the proportion of long-double potentials was 4 +/- 2%, 12 +/- 3%, and 18 +/- 7% (P < .05); the proportion of fragmented complexes was 2 +/- 2%, 6 +/- 3%, and 10 +/- 4% (P < .05), respectively. During electrically induced and self-terminating episodes of AF, no preferential anatomic sites for double or fragmented potentials were found in the right atrium.
Conclusions:
The morphology of single unipolar electrograms during AF reflects the occurrence of various specific patterns of conduction. This might be used to differentiate between different types of AF and to identify regions with structural conduction disturbances involved in perpetuation of chronic AF.
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Dysrhythmias III: Characteristics of Dysrhythmias
Dysrhythmias IV: Characteristics of Bradyarrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias