Effects of Exposure of Formaldehyde to a Rat Model of Atopic Dermatitis Induced by Neonatal Capsaicin Treatment
Published on: September 27, 2017
A recommended occupational exposure limit for formaldehyde based on irritation
D Paustenbach1, Y Alarie, T Kulle
1McLaren/Hart/ChemRisk, Alameda, CA 94501, USA.
The Industrial Health Foundation panel recommends an occupational exposure limit (OEL) for formaldehyde of 0.3 ppm (8-h TWA) and a ceiling value (CV) of 1.0 ppm to prevent irritation. This guideline is based on human studies and aims to protect workers from adverse effects.
Area of Science:
- Occupational Health
- Toxicology
- Environmental Health
Background:
- Regulatory agencies and professional societies recommend occupational exposure limits (OELs) for formaldehyde.
- A panel of experts was convened to establish an OEL that prevents irritation.
Purpose of the Study:
- To determine an occupational exposure limit (OEL) for formaldehyde that prevents irritation.
- To evaluate existing scientific literature and mathematical models for formaldehyde exposure.
- To provide recommendations for safe formaldehyde exposure levels in occupational and indoor environments.
Main Methods:
- Critiqued approximately 150 scientific articles on formaldehyde exposure and human irritation.
- Evaluated a mathematical model for predicting safe irritant exposure levels.
- Analyzed data from controlled studies involving human volunteers and occupational settings.
Main Results:
- Eye irritation in most individuals does not occur below 1.0 ppm formaldehyde.
- Moderate to severe irritation of eyes, nose, and throat occurs above 2.0-3.0 ppm.
- At 0.3 ppm (8-h TWA), eye irritation rates are similar to clean air exposure.
- At 0.5 ppm (8-h TWA), the majority of workers (80%) did not experience eye irritation.
Conclusions:
- Recommended an OEL of 0.3 ppm (8-h TWA) and a ceiling value (CV) of 1.0 ppm to prevent formaldehyde-induced irritation.
- Found the ACGIH TLV of 0.3 ppm as a ceiling value to be unnecessarily restrictive.
- Concluded that indoor formaldehyde concentrations below 0.1 ppm should prevent irritation for virtually all individuals.
- Determined no evidence of hypersensitivity or sensitization to formaldehyde via inhalation.
- Observed that individuals with asthma respond similarly to healthy individuals up to 3.0 ppm exposure.
More Related Videos
14:20High Throughput SiRNA Screening for Chloropicrin and Hydrogen Fluoride-Induced Cornea Epithelial Cell Injury
Published on: June 16, 2018
10:10Assessment of the Acute Inhalation Toxicity of Airborne Particles by Exposing Cultivated Human Lung Cells at the Air-Liquid Interface
Published on: February 23, 2020